PAGE 28 — LT12D50SA LIGHT TOWER • OPERATION MANUAL — REV. #0 (03/16/09)

NORMAL SHUTDOWN

If a load is attached to the generator of the light tower,

1.

remove the load.

Set the four lamp circuit breakers on the control panel

2.

to the OFF position.

Place the MAIN circuit breaker on the control panel to

3.

the OFF position.

Wait a few seconds and observe that all four lamps

4.

are OFF.

Let the engine idle for a few minutes with no load.

5.

Turn the ignition key to the OFF position. Store key in

6.

a safe location.

Lower light tower mast and place in stow position as

7.

outlined in this manual.

Place outriggers in tow position, and remove chock

8.

blocks.

Store light tower in a clean, dry location out of the reach

9.

of children and unauthorized personnel.

EMERGENCY SHUTDOWN

Turn the ignition key to the OFF position and turn all

1.

circuit breakers to the OFF position.

NOTICE

Failure to turn the breakers off may damage the
generator.

NOTICE

If servicing is required, allow lamps to cool for about
15 minutes before removing lamps.

OPERATION