beautypg.com

Lcd display/generator control box – Multiquip DCA20SPXU2D User Manual

Page 20

background image

PAGE 20 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/25/11)

LCD DISPLAY/GENERATOR CONTROL BOX

The defi nitions below describe the monitoring parameters
of the Digital Control Panel Display(Figure 6).

Figure 6. LCD Display

1. VOLT — Indicates the phase to phase reading at the

output terminals.

2. AMP — Indicates the current flowing to the load

connected at the output terminals.

3. PH — Indicates the voltage phase.

4. Hz — Indicates output frequency of the generator.

5. OIL

During normal operation this gauge should read

between 35 ~65 psi. (241~448 kPa). When starting the
generator the oil pressure may read a little higher, but
after the engine warms up the oil pressure should return
to the correct pressure range.

6.

FUEL

— Indicates the percent of fuel remaining in the

fuel tank.

7. TEMP

During normal operation this gauge be should read

between 167°~203°F (75° ~95°C).

8.

BATT

— When the engine is running this value should

be greater than 13 VDC.

Located behind the generator control panel is the Generator
Control Box. This box contains some of the necessary
electronic components required to make the generator
function.

The Control Box is equipped with the following major
components:

 Over-Current Relay

 Automatic Voltage Regulator (AVR)

 Starter Relay

 Current Transformer

 Voltage Selector Switch

 Main Circuit Breaker

NOTICE

Via the internet, go to www. basler.com, for more detail
Digital Control Panel operating instructions.