beautypg.com

Maintenance – Multiquip J36E2 User Manual

Page 27

background image

J36e2 elecTric WalK-BeHiND TrOWel • OperaTiON aND parTs maNUal — rev. #0 (07/24/12) — page 27

1. Unscrew the locking bolts on the adjustment fixture and

place the trowel arm (lever attached) into the fixture

channel as shown in Figure 27.

2. Ensure the fixture arm is in the up position.
3. A thin shim may be required to cover the blade holes

on the trowel arm. Make sure to align the trowel

adjustment bolt with the fixture adjustment bolt.

Figure 27. Trowel Arm Adjustment Fixture

4. Use an allen wrench to tighten the locking bolts

securing the trowel arm in place.

5. Adjust the bolt distance shown in Figure 27 to match

one of the arms. The other arms will be adjusted to

match this distance.

6. Loosen the locking nut on the trowel arm lever, then

turn the trowel arm adjusting bolt until it barely touches

(.010") the fixture adjusting bolt.

7. Once the correct adjustment is made, tighten the lock

nut on the trowel arm to lock in place.

8. Loosen locking nuts on the adjustment fixture, and

remove trowel arm.

9. Repeat steps for the remaining trowel arms.

reassemBly

1. Clean and examine the upper/lower wear plates and

thrust collar. Examine the entire spider assembly. Wire

brush any concrete or rust buildup. If any of the spider

components are found to be damaged or out of round,

replace them.

2. Make sure that the bronze trowel arm bushing is not

damage or out of round. Clean the bushing if necessary.

If the bronze bushing is damaged or worn, replace it.

ARM

SHIM

LOCKING

BOLTS

TROWEL ARM

ADJUSTMENT FIXTURE

TROWEL

ARM

LEVER

FIXTURE

ARM

DISTANCE

.010 INCH

ADJUSTMENT

BOLT

ADJUSTMENT

BOLT

MaintenanCe

3. Reinstall bronze bushing onto trowel arm.
4. Repeat steps 2 -3 for each trowel arm.
5. Make sure that the spring tensioner is in the correct

position to exert tension on the trowel arm.

6. Insert all trowel arms with levers into spider plate (with

bronze bushing already installed) using care to align

grease hole on bronze bushing with grease hole fitting

on spider plate.

7. Lock trowel arms in place by tightening the hex head

bolt with zerk grease fitting and jam nut.

8. Reinstall the blades onto the trowel arms.
9. Install stabilizer ring onto spider assembly.
10. Reinstall lower wear plate, thrust collar and upper wear

ring in the reverse order that they were disassembled

onto the spider shaft. Make sure that there is little or

no lateral movement between the thrust collar and the

spider shaft.

11. Carefully lift the upper trowel assembly, line up the

keyway on gear box main shaft and insert into spider

assembly.

12. Reinstall square head cone point into spider plate and

tighten in place. Tighten jam nut. Use care in making

sure point of set screw engages groove in gear box

main shaft.

13. Lubricate all grease points (zerk fittings) with premium

"Lithum 12" based grease, conforming to NLG1 Grade

#2 consistency.