Multiquip LS-50TD User Manual
Page 24

PAGE 24 — MAYCO LS-40D/LS-40TD/LS-50TD PUMP — OPERATION AND PARTS MANUAL — REV. #11 (09/16/11)
LS-40D/LS-40TD/LS-50TD PUMP — INSPECTION
BEFORE STARTING
1. Read safety instructions at the
beginning of manual.
2. Clean the
entire pump, removing dirt and dust, particu-
larly the engine cooling air inlet, and heat exchanger.
3. Check the
air filter for dirt and dust. If air filter is dirty,
replace air filter with a new one as required.
4. Check fastening nuts and bolts for tightness.
FUEL CHECK
5.
Check the fuel gauge built into the fuel tank cap
(Figure 9) to determine if the pump's engine fuel is low.
Refuel as needed
See Figures 6, 7, 8 for the location of any
control or component referenced in this
section.
Handle fuel safely. Diesel fuel is highly
flammable and
can be dangerous if mishandled. DO NOT
smoke while
refueling. DO NOT attempt to refuel mixer if the engine
is hot or running. ALWAYS
allow engine to cool before
refueling.
Figure 10. Adding Diesel Fuel
Figure 9. Fuel Cap Gauge
6.
If fuel is low, remove fuel filler cap and fill with
#2
diesel fuel (Figure 10).
CAUTION - GENERAL SAFTEY GUIDELINES
ALWAYS wear approved
eye and
hearing protection before
operating the pump .
NEVER place hands or feet inside the
hopper.
ALWAYS make while the engine is running. ALWAYS
shut-down the engine before performing any kind of
maintenance service on the pump.
NEVER operate the pumps's engine
with the engine hood removed. The
possibility exists of
hands, long hair,
and
clothing becoming entangled with
the V-belt, causing injury and bodily
harm.
NEVER operate the pump in a
confined area or enclosed area
structure that does not provide ample
free flow of air.
WARNING - EXPLOSIVE FUEL
Diesel fuel is extremely flammable, and
its vapors can cause an explosion if
ignited. DO NOT start the engine near
spilled fuel or combustible fluids. DO
NOT fill the fuel tank while the engine
is running or hot.
DO NOT overfill tank, since spilled fuel could ignite if it
comes into contact with hot engine parts or sparks from
the ignition system. Store fuel in approved containers,
in well-ventilated areas and away from sparks and
flames. NEVER use fuel as a cleaning agent.
WARNING - EXPLOSIVE FUEL