Start-up – Multiquip WM63h8 User Manual
Page 22
page 22 — wm63-series mixer • operaTion and parTs manual — rev. #0 (09/27/12)
start-up
This section is intended to assist the operator with the initial
start-up of the unit. It is extremely important that
this section be read carefully before attempting
to use the mixer in the field.
do noT use your
mixer until this section is thoroughly understood.
The following steps outline the procedure for starting the
engine.
1. Move the fuel shut-off lever (Figure 14) to the ON
position.
Figure 14. Fuel Shut-Off Lever
2. To start a cold engine, move the choke lever (Figure
15) to the CLOSED position.
Figure 15. Choke Lever
warning
Failure to understand the operation of the mixer could
result in severe damage to the mixer or personal injury.
See Figure 4 for the location of any control referenced
in this manual.
CauTion
never operate the mixer in a confined
area or enclosed area structure that does
not provide ample free flow of air.
3. Move the throttle lever (Figure 16) away from the slow
position, about 1/3 of the way toward the fast position.
Figure 16. Throttle Lever
4. Turn the engine switch (Figure 17) to the ON position.
Figure 17. Engine On/Off Switch
5. The main start/stop switch located on the engine cover
(Figure 18) is used to start and stop the engine. Pull
this switch outward to start the engine.
Figure 18. Start/Stop Switch
PULL OUT
TO START ENGINE