Resetting the Thermal Overloads

The thermal overloads of the hydraulic power unit (HPU) can be tripped
by the following conditions:

Poor motor ventilation

The output pressure is set too high

A pump or motor is seizing

The thermal overloads are located in the control box.

Do not open the control box unless the line voltage is turned off. When
power is present in the control box, high voltage and amperages are also
present.

You can be electrocuted if you touch the wrong component in the control
box.

Disconnect the HPU from power before opening the control box.

1.

Check the thermal overloads of the power source to the HPU.

If it has tripped, reset it and try restarting the HPU.

If the thermal overloads have
not tripped, remove power
from the HPU before opening
the control panel.

2.

Unscrew the clamps holding the
control panel’s door shut.

3.

Check the thermal overloads
tripped indicator. If it has tripped,
press RESET on the overload.

4.

Check for a blown fuse. The
replacement fuse must have the
same rating as the blown fuse.

5.

Shut the control box door. Use the
clamps to hold it in place.

6.

Reconnect the HPU to its electrical power source.

7.

Restart the HPU. If the HPU will not restart or shuts down right away,
call MTS.

WARNING

Thermal
Overloads

Reset
Button

Tripped
Indicator

Fuse