beautypg.com

MTS Series 685 Hydraulic Grip Supply User Manual

Page 31

background image

Series 685 Grip Supply Installation Procedure

Series 685 Grip Supply Product Information

Installation

31

4. Remove the 1/2 inch NPT plug.

The plug was installed in the top of the reservoir for shipment from the
factory.

5. Check the fluid in the reservoir.

The reservoir contains 8.3 liters (2.2 gallons) when the fluid is up to the
“High” mark on the sight gage and 6.1 liters (1.6 gallons) when the level is
at the “Low” mark.

Add fluid to the reservoir as necessary to bring the fluid level to or near the
“High” mark on the sight gage. An extra gallon is shipped with the
hydraulic grip supply. Never add another fluid other than Mobil 525 SHC to
the reservoir.

6. Install the breather.

100 V / 50 Hz / 1 phase

100 V

Common

110 V / 50 Hz / 1 phase

110 V

Common

200 V / 50 Hz / 1 phase

200 V

Common

220 V / 50 Hz / 1 phase

220 V

Common

240 V / 50 Hz / 1 phase

240 V

Common

C

USTOMER

-S

UPPLIED

P

OWER

L1

L2

Sight gage

NPT/Breather