PCL-2

CLIP-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

P

anel

o

verview

PANEL PROFILE

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any Clip-Loc roofing panel is 1:12. If slope is less than

3:12, apply a continuous bead of tube sealant on inside of clip leg and a row on top of the male leg.

Clip-Loc is designed to be utilized over open structural framing, but can easily be used with a solid substrate.

The recommended substrate is

5

/

8

" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use

a properly aligned and uniform substructure.

Clip-Loc panels are available in 16" width with a 1

5

/

8

" rib height.

Lengths under 5'-0" on panels with striations and lengths under 7'-0" for flat panels are available with

some cutting restrictions. Maximum recommended panel length is 45'-0". Longer panels require additional

consideration in packaging, shipping, and erection. Please consult your Metal Sales branch for recommenda-

tions (see PGI-2 and 3 for locations).

Clip-Loc panels are available in 24 and 22 gauge. Minimum quantity may apply.

Commercial and Industrial panel.

Concealed Clip System.

The fastener selection guide should be consulted for choosing proper fasteners for specific applications.

Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).

Steel grade 50, per ASTM A-792

16" Coverage

8"

1

5

/

8

"

C

Barb

(12"o.c.)

PERFORMANCE TEST

UL 580, ASTM E-15922, ASTM E-1646, ASTM E-1680, UL 2218, UL 790, UL 263, UL 1897,

AISI Diaphragm

*

Acrylic Coated Galvalume

®

(ACG) / ASTM A-792 - AZ55

Prepainted Galvalume / ASTM A-792 - AZ50

**

Fluorocarbon (PVDF)

*

Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.

**