beautypg.com

4 manual mode, Ich 500, Adjustment options – Memmert Universal ovens U, Incubators I, Sterilisers S User Manual

Page 26: Operation and control, Fan speed

background image

26

D24022 | Date 10/2014

Operation and control

5.4.4 Manual mode

In this operating mode, the appliance runs in permanent operation at the values set on the

ControlCOCKPIT.

Adjustment options

Adjustment options

As described in chapter 5.4.2, you can set the following parameters after pressing the cor-

responding activation key (in any sequence):
Temperature

Temperature

Adjustment range: model dependent (see nameplate and technical

date on page 13)

Heating operation is indicated by the symbol.

symbol.

You can select °C or °F as the temperature unit displayed (see

page 36).

24

.4°C

TEMP

180

.4

°C

Set

Air flap position

Air flap position
Adjustment range: 0 % (closed, recirculating operation) to 100 %

(completely opened, fresh air operation) in steps of 10%

FLAP

%

40

Fan speed

Fan speed

(only for UF/IF/SF appliances)
Adjustment range: 0 to 100 % in steps of 10%

FAN

%

50

5.4.5 Operation with digital backwards counter with target time setting,

adjustable from 1 minute to 99 days (Timer)

In timer operation, you can adjust the time the appliance runs at the set value.

1. Press the activation key to the left of

the timer display. The timer display is

activated.

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

.5°C

100

ICH 500

MENU

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

MENU

TIMER

-

Ende 9:00 23.11.

--

h

-

m

2. Turn the turn control until the desired

duration is displayed – in this example 4

hours 30 minutes. The approximate end

time is shown beneath, in a smaller font.

Hauptschalter

>

Zu der Typenbezeichnung gibt es momentan drei Entwurfsrichtungen,

ich kann Ihnen noch nicht sagen, ob Memmert hierzu schon eine Entscheidung

getroffen hat.

Die hier gezeigt Variante, ist die von uns empfohlene Richtung.

UF 110

PLUS

ON

344

.4

444

4

.

TEMP

Set

°C

°C

FLAP

40

%

TIMER

h

d

10

02

End

Sept.

29

22 24

FAN

%

0

%

100

ALARM

max

444

.4°C

auto

+/-

0.0

K

min

444

.4°C

O

O

ON

N

N

N

O

O

N

O

Manu

44.Sept

TIMER

End

0

13:30 23.11.

04

m

h

3

Up to a duration of 23 hours 59 minutes, the time is displayed in hh:mm (hours:minutes)

format. For 24 hours and more, the format dd:hh (days:hours) is used. The maximum