beautypg.com

2 function, 3 material, 4 electrical equipment – Memmert Universal ovens U, Incubators I, Sterilisers S User Manual

Page 11

background image

D24022 | Date 10/2014

11

Setup and description

2.2 Function

Appliances of the UN, SN and

IN type series feature

natural circulation (convec-

tion). For the UF, SF and IF

type series, air is circulated

by a fan at the working

chamber rear panel Fig. 3 ,

No. 1). It increases the air

flow and provides stronger

horizontal forced air

circulation than natural

convection.
In both the convection and

fan ventilated appliances,

supply air (2) is preheated

in a pre-heating chamber

(3). Through the ventilation

slits in the side panel of the

working chamber, the pre-

heated air is introduced into

the interior of the chamber.

The supply and exhaust air

(5) volume (air change) is

controlled by the air flap

(4) on the rear panel of the

appliance.

2.3 Material

For the outer housing, MEMMERT deploys stainless steel (Mat.No. 1.4016 – ASTM 430) and

for the interior, stainless steel (Mat.No. 1.4301 – ASTM 304) is used, which stands out through

its high stability, optimal hygienic properties and corrosion-resistance towards many (but not

all!) chemical compounds (caution for example with chlorine compounds).
The chamber load for the appliance must be carefully checked for chemical compatibility with

the materials mentioned. A material resistance table can be requested from the manufacturer.

2.4 Electrical equipment

Operating voltage and current consumption: See nameplate

Protection class I, i.e. operating insulation with PE conductor in accordance with EN 61010

Protection type IP 20 acc. to EN 60 529

Interference suppression acc. to EN 55011 class B

Appliance fuse: Fusible link 250 V/15 A quick-blow

The temperature controller is protected with a miniature fuse 100 mA (160 mA at 115 V)

Fig. 3

Function

1 Fan

2 Fresh air

3 Pre-heating chamber

4 Air flap

Pre-heating chamber

Pre-heating chamber

5 Exhaust air

Air flap

Air flap