Manual Calibration Instructions for Controller
Figure S
Power
Harness
Port
Ramp
Harness
Port
Data
Harness
Port
J9 Port
Calibrate
Button
Stow Limit
Potentiometer
Deploy Limit
Potentiometer
Calibrate
Reset Button
Press the “Calibrate” button. Once pressed, the
calibrate LED should turn on.
Adjust the Deploy Limit potentiometer to the obstruc-
tion sensing level desired (see Figure S). Rotating
the potentiometer counterclockwise increases the
force that the ramp will exert when it is deploying.
Caution: Ensure that the force exerted is not exces-
sive. It is recommended to adjust the potentiometer
in small amounts and check operation after each
adjustment.
Adjust the Stow Limit potentiometer to the obstruc-
tion sensing level desired. Rotating the potentiom-
eter counterclockwise increases the force that the
ramp will exert when it is stowing.
Caution: Ensure that the force exerted is not exces-
sive. It is recommended to adjust the potentiometer
in small amounts and check operation after each
adjustment.
Once the desired force levels are reached, press the
“Calibrate” button a second time to store the set-
tings. Ensure the calibrate LED is off before return-
ing the ramp to service.