Warning, Ramp installation – Braun RA500 User Manual

Page 30

background image

Page 28

WARNING

WARNING

Risk of electrical

shock! Use extra

care when making

electrical connec-

tions.

Risk of electrical fire!

Use extra care when

making electrical

connections.

WARNING

Cable

Clip

Cable Tie

Cable

(typical)

Vehicle

Floor

Vehicle

Floor

Framing

Member

Self-Tap Screw

Secure all cables using cable

ties and/or cable clips (mount

clips with self-tap screws).

Carefully connect the power “battery” lead

wire to the Positive (+) battery post.

Chassis Ground Corrosion: When

mounting chassis ground cables, remove

undercoating, dirt, rust, etc. from the fram-

ing member around the mounting holes.

Apply a protective coating to mounting

holes to prevent corrosion. Apply grease

to ground cable terminals and mounting

hardware. Failure to do so will void war-

ranty of certain electrical components.

The ramp installer provides an

appropriate control switch for the

end user. One-touch operation

using a single "operate" button

(switch) or two-way toggle opera-

tion with dedicated switches for

the stow and deploy command

are options.

Installer connections are listed in

the table on the following page.

Strip wires, crimp and install con-

tacts as specified in instructions

supplied with the power connec-

tor (Molex 2-pin) and the data

connector (Amp 4-pin).

The Positive (+) “battery” lead wire must

be protected by an in-line 25 ampere

fuse or circuit breaker (installer pro-

vided).

Do not connect the power “battery” lead

wire to the battery until all other connec-

tions are made.

Connect the 4-pin data harness plug to

the mating connector on the controller.

Connect the 2-pin Power harness plug to

the mating connector on the controller.

Electrical Connections

AI 18760 006.ai

Figure Q

RAMP INSTALLATION

Route cables clear

of exhaust system,

other hot areas and

moving parts. Failure

to do so may result

in serious bodily

injury and/or property

damage.

Battery / Ground Connections