beautypg.com

Status display, Commissioning – Lenze EMF2141IB 2141 LON User Manual

Page 40

background image

5

Commissioning

Status display

EDKMF2141 DE/EN/FR 2.0

L

40

Pos

LED status

Explanation

-20-

1

Green bus LED (voltage supply)

1

ON

Communication module is supplied with voltage and connected to the
controller.

OFF

Communication module is not supplied with voltage. The drive controller
or external voltage supply is switched off.

BLINKING

Communication modul is supplied with voltage but has not (yet) been
connected to the controller because

l

the communication module has not been plugged onto the controller
properly.

l

the data transfer of/to the drive controller is still not possible (e. g. the
drive controller is in the initialisation phase).

2

Yellow bus LED (communication)

2

OFF

Communication module has not been initialised yet.

BLINKING

LON communication active

3

Red and green drive LED indicate the operating mode of the drive controller 82XX or
93XX (see the Operating Instructions of the drive controller)

4

Service LED

4

OFF

Normal operating status

BLINKING

Communication module has not been configured yet

ON

Not program available in Neuron.