beautypg.com

Lenze EMF2141IB 2141 LON User Manual

Page 39

background image

5

Commissioning

Initial switch-on

EDKMF2141 DE/EN/FR 2.0

39

L

Protection against uncontrolled restart

-19-

)

)

)

)

Note!

After a fault (e.g. short-term mains failure) a restart of the drive is not
always wanted.

l

By setting L-C0142 = 0, the drive can be inhibited if
– the corresponding controller sets a ” fault message“
– the fault is active for more than 0.5 s

Parameter function:

l

L-C0142 = 0
– Controller remains inhibited (even if the fault is not active any longer)
– The drive restarts in a controlled mode: LOW-HIGH transition at one

of the inputs for ” Controller inhibit“ (CINH, e.g. at terminal X5/28)

l

L-C0142 = 1
– Uncontrolled restart of the controller possible

Show/Hide Bookmarks