3.5
L_8200StatusWord − Output of boolean status signals
Function library Lenze8200Drive.lib
Functions/function blocks
3−16
L
Lenze8200Drive.lib EN 1.0
3.5
L_8200StatusWord − Output of boolean status signals
Function block
This FB is used to divide the status word received by the frequency inverter which is provided by the
FB L_8200DataControl at the FB output wStatusData into boolean status signals.
L_8200StatusWord
bDCTRL1_CINH
CTRL
wStatusData
bDCTRL1_TRIP
bFIXED_RESERVE_9
bFIXED_RESERVE_11
bFIXED_RESERVE_12
bDCTRL1_OH_WARN
bNSET1_RFG1_NOUT
bNSET1_RFG1_I
bPCTRL1_QMIN
bDCTRL_NOUT
bMCTRL_IMAX
bDCTRL_IMP
bDCTRL1_RDY
bFIXED_RESERVE_10
bDCTRL1_OV
bDCTRL1_CCW
FB call in:
þ Cyclic task
(PLC_PRG)
þ Time−controlled task
(INTERVAL)
þ Event−controlled task
(EVENT)
o Interrupt task
Inputs
Data type
Information/possible settings
wStatusData
Word
Status word received by the frequency inverter.
·
Connect this input with the output wStatusData
of the FB L_8200DataControl. (
^ 3−10)
Outputs
Data type
Value/meaning
bDCTRL1_RDY
Bool
Detailed information about the meaning of the individual status signals can be found in the
Operating Instructions for the 8200 frequency inverter.
Note!
The composition of the status word depends on the parameterisation of the frequency inverter!
·
The names of the status signals contained in this Manual have been adapted to the commented
assignments in the FB L_8200Parameter.(
^ 3−2)
bDCTRL_IMP
Bool
bMCTRL_IMAX
Bool
bNSET1_RFG1_NOUT
Bool
bNSET1_RFG1_I
Bool
bPCTRL1_QMIN
Bool
bDCTRL_NOUT
Bool
bDCTRL1_CINH
Bool
bDCTRL1_TRIP
Bool
bFIXED_RESERVE_9
Bool
bFIXED_RESERVE_10
Bool
bFIXED_RESERVE_11
Bool
bFIXED_RESERVE_12
Bool
bDCTRL1_OH_WARN
Bool
bDCTRL1_OV
Bool
bDCTRL1_CCW
Bool