Cable cross−sections and screw−tightening torques, Installation – Lenze E82ZAFVC010 User Manual
Page 27

Installation
Electrical installation
Cable cross−sections and screw−tightening torques
l
27
EDS82ZAFVCxxx EN 4.0
5.2.5
Cable cross−sections and screw−tightening torques
Function module E82ZAFVC001
Range
Values
Electrical connection
Terminal strip with screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.0 mm
2
(AWG 18)
with wire end ferrule, without plastic sleeve
0.5 mm
2
(AWG 20)
with wire end ferrule, with plastic sleeve
0.5 mm
2
(AWG 20)
Tightening torque
0.22 ... 0.25 Nm (1.9 ... 2.2 lb−in)
Bare end
5 mm
Function module E82ZAFVC010
Field
Values
Electrical connection
Plug connector with double screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Tightening torque
0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)
Stripping length
10 mm
Field
Values
Electrical connection
2−pin plug connector with spring connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Stripping length
9 mm