Appendix, Codes – Lenze EMF2192IB User Manual
Page 59

Appendix
Codes
l
59
EDSMF2192IB EN 3.1
Parameter
C1825
Name
AIF output double words (from the standard device)
Data type: UINT32
Index: 22750
dec
= 58DE
hex
Display of the process output data
Display area
(min. value | unit | max. value)
0x00000000
0xFFFFFFFF
Subcodes
Information
C1825/1
...
C1825/n
Parameter
C1830
Name
Bus status
Data type: FIX32
Index: 22745
dec
= 58D9
hex
Bit−coded display of the current bus status
^ 40
Display area
(min. value | unit | max. value)
0x00000000
0xFFFFFFFF
Bits
(read only)
Information
Bit 0 EtherCAT bus status in accordance
with CiA DS301
0: Unknown
1: Init
2: Pre−operational
3: Bootstrap
4: Safe−operational
8: Operational
...
Bit 7
Bit 8 Not assigned
...
Bit 12
Bit 13 SYNC_bProcessDataExpected
New process data were expected during the
application cycle.
Bit 14 SYNC_bProcessDataInvalid
New/last process data are invalid.
l
Checksum error
l
No telegram received
Bit 15 EtherCAT error flag
Parameter
C1850
Name
Station alias address
Data type: FIX32
Index: 22725
dec
= 58C5
hex
Specification of the station address if the master is used to address the alias
l
0: no alias address
l
65535: Alias address preselection in the slave
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Parameter
C1882
Name
Response when exiting "Operational"
Data type: FIX32
Index: 22693
dec
= 58A5
hex
Adjustable response for the process data monitoring
Selection list
(Lenze setting printed in bold)
Information
0 No response
1 Error (TRIP)
2 Controller inhibit (CINH)
3 Quick stop (QSP)