Parameter data transfer
Reading and writing parameters
Reading parameters (expedited upload)
l
45
EDSMF2192IB EN 3.1
SDO Upload Expedited Response
An "SDO Upload Expedited Response" takes place if the data length of the parameter data
to be read amounts to up to 4 bytes.
Detailed breakdown of the data for an "SDO Upload Expedited Response":
SDO frame
area
Data field
Data type / length
Value / description
Mailbox Header
Length
WORD
2 bytes
0x0A: Length of the mailbox service data
Address
WORD
2 bytes
Station address of the source if an EtherCAT master is the instructing
party.
Station address of the target if an EtherCAT slave is the instructing
party.
Channel
WORD
6 bits (0 ... 5)
0x00: Reserved
Priority
2 bits (6, 7)
0x00: Lowest priority
...
0x03: Highest priority
Type
4 bits (8 ... 11)
0x03: CANopen over EtherCAT (CoE)
Reserved
4 bits (12 ... 15)
0x00
CANopen Header
Number
WORD
9 bits (0 ... 8)
0x00
Reserved
3 bits (9 ... 11)
0x00
Service
4 bits (12 ... 15)
0x03: SDO Response
SDO
Size indicator
BYTE
1 bit (0)
0x01: Size of the data in "data set size"
Transfer type
1 bit (1)
0x01: Expedited transfer
Data set size
2 bits (2, 3)
0x00: 4 bytes data
0x01: 3 bytes data
0x02: 2 bytes data
0x03: 1 byte data
Complete access
1 bit (4)
0x00: The entry addressed with index and subindex is read.
0x01: The complete object is read.
Command specifier
3 bits (5 ... 7)
0x02: Upload Response
Index
WORD
2 bytes
Index of the object
Subindex
BYTE
1 byte
Subindex of the object
0x00 or 0x01 if "complete access" = 0x01.
Data
DWORD
4 bytes
Data of the object