C13899 | station address, C13900 | firmware product type, C13901 | firmware compilation date – Lenze E84Dxxxx User Manual
Page 85: C13902 | firmware version, C13920 | display: dip switch setting, C13920, C13899, Communication manual 8400 protec profibus

Communication manual 8400 protec PROFIBUS
Parameter reference
Parameters relevant for the communication
85
L
EDS84DPBUS EN 2.0 - 09/2010
C13899
C13900
C13901
C13902
C13920
Parameter | Name:
C13899 | Station address
Data type: UNSIGNED_8
Index: 10676
d
= 29B4
h
Optional setting of the station address (instead of setting via DIP switches 1 ... 64)
• The station address set here only becomes effective if the DIP switches 1 ... 64 have been set to OFF prior to mains
switching.
• The active station address is displayed under
Note!
A change in the station address will not be effective until the "Save parameter set" command was executed and
another mains switching for the module / drive was performed.
Setting the station address ( 24)
Setting range
(min. value | unit | max. value)
Lenze setting
3
126 3
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX ; COM MOT
Parameter | Name:
C13900 | Firmware product type
Data type: VISIBLE_STRING
Index: 10675
d
= 29B3
h
Display of the product type (string with a length of 8 bytes)
• The following identification code is displayed: "E84DFYPM".
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 10674
d
= 29B2
h
Display of the compilation date of the firmware (string with a length of 20 bytes)
• The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673
d
= 29B1
h
Display of the firmware version (string with a length of 5 bytes)
• An identification code is displayed, e.g. "01.00.00.00".
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13920 | Display: DIP switch setting
Data type: UNSIGNED_8
Index: 10655
d
= 299F
h
Display of the current DIP switch setting
• The displayed value corresponds to the sum of the individual DIP switch values 1 ... 64.
• The active station address is displayed under
Setting the station address ( 24)
Display area
(min. value | unit | max. value)
0
255
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT