3 technical data, 2 protocol data, Technical data – Lenze E84Dxxxx User Manual
Page 13: Protocol data, Communication manual 8400 protec profibus, 3technical data

Communication manual 8400 protec PROFIBUS
Technical data
General data and operating conditions of the PROFIBUS
13
L
EDS84DPBUS EN 2.0 - 09/2010
3
Technical data
3.1
General data and operating conditions of the PROFIBUS
3.2
Protocol data
Mounting instructions "Inverter Drives 8400 protec"
Here you will find information on general technical data, operating conditions
and rated data of the device.
Area
Values
Communication profile
• PROFIBUS DP-V0 (DRIVECOM)
• PROFIBUS DP-V1 (PROFIdrive)
Communication medium
RS485
Interface
9-pole Sub-D socket or M12 socket
Network topology
• Line (without repeater)
• Tree/line (with repeater)
Node
PROFIBUS slave
Number of slaves
• max. 31 (without repeater)
• max. 125 (with repeater)
Max. cable length
1200 m (depending on the selected baud rate and the cable type used)
PNO identification number
0xE84D
Baud rate for cable type A (EN 50170) 9.6 kbps ... 12 Mbps (automatic detection)
Area
Values
Process data words (PCD)
1 ... 16 words (32 bytes)
PROFIsafe messages
4 words (8 bytes)
Cyclic parameter data channel (DP-
V0)
4 words (8 bytes)
Acyclic parameter data channel (DP-
V1)
Max. 240 bytes
PROFIBUS user data length
1 ... 16 words process data channel + 4 words parameter data channel
(10 ... 40 bytes)