Parameter reference
Parameters relevant for the communication
79
L
EDS84DPBUS EN 2.0 - 09/2010
13
Parameter reference
This chapter complements the parameter list and table of attributes in the software
manual and the »Engineer« online help for the Inverter Drive 8400 protec by the PROFIBUS
parameters relevant for the communication.
13.1
Parameters relevant for the communication
This chapter lists the PROFIBUS parameters in numerically ascending order.
C13850
C13851
Software manual/»Engineer« online help for the Inverter Drive 8400 protec
Here you can find general information on parameters.
Parameter | Name:
C13850 | All words to master
Data type: UNSIGNED_16
Index: 10725
d
= 29E5
h
Display of the process data words which are transmitted from the controller to the master.
• In the subcodes 1 to 16, all process data words to the master are displayed. However, only the configured process
data words are valid.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13850/1
...
C13850/16
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724
d
= 29E4
h
Display of the process data words which are transmitted from the master to the controller.
• In the subcodes 1 to 16, all process data words from the master are displayed. However, only the configured
process data words are valid.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13851/1
...
C13851/16
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT