beautypg.com

8 troubleshooting and fault elimination, Troubleshooting and fault elimination, Troubleshooting and fault elimination 8 – Lenze DISCO−Variable speed drive User Manual

Page 28: 8troubleshooting and fault elimination

background image

Troubleshooting and fault elimination

8

l

28

BA 11.5032−EN 3.0

8

Troubleshooting and fault elimination

Fault

Possible cause

Remedy

Drive does not start

Voltage supply interrupted

Check connection

Faulty electrical connection

Check that supply voltage matches
nameplate data

Excessive load

Reduce load
Check drive−machine assignment

Motor runs, gearbox does not

Coupling components are missing or
defective

Check mounting

Gearbox is defective

Inform Lenze Service

Unusual running noise

Overload

Reduce load
Check drive−machine assignment

Damage to the gearbox or motor

Inform Lenze Service

Excessive temperature

Overload

Reduce load
Check drive−machine assignment

Inadequate heat dissipation

Improve cooling air flow
Clean gearbox/motor

Lack of lubricant

Top up lubricant according to regulations

Loose fixing elements

Vibrations

Avoid vibrations