Wiring the device modules, Communication modules, Dip switch – Lenze E94AMHE User Manual
Page 71: For the dip switches that are placed at the front, The node address (labelling "1" ... "64") and, Baud rate (labelling "a" ... "d") can be set, Displays
Wiring the device modules
Communication modules
l
71
EDK94AMH24 DE/EN/FR/ES/IT 3.1
DIP switch
Pos.
Description
0
Addressing of the bus node
Baud
CAN Address
O
N
c
d
b
a
64
32
16
8
4
2
1
A
9400CAN003
Fig. 8−3
Arrangement and labelling of the DIP switches
For the DIP switches that are placed at the front
ƒ
the node address (labelling "1" ... "64") and
ƒ
baud rate (labelling "a" ... "d")
can be set.
)
Note!
If all address switches adopt the "OFF" position when the basic device is
switched on, the configurations of codes C00350 (nodes address) and C00351
(baud rate) apply.
Switch the voltage supply of the basic device off and then on again to activate
altered settings.
Setting the node address
The node address of the drive is calculated from the sum of all address switches in the "ON"
position.
Setting the baud rate
d
c
b
a
Baud rate
OFF
ON
ON
OFF
10 kbit/s
OFF
ON
OFF
ON
20 kbit/s
OFF
OFF
ON
ON
50 kbit/s
OFF
OFF
ON
OFF
125 kBit/s
OFF
OFF
OFF
ON
250 kbit/s
OFF
OFF
OFF
OFF
500 kbit/s
ON
ON
ON
OFF
800 kbit/s
OFF
ON
OFF
OFF
1000 kbit/s
OFF
ON
ON
ON
Auto baud
Displays
Pos.
Colour
Condition
Description
MS
Green
On
Communication module is supplied with voltage.
DE
Red
On
Communication module is not accepted by the standard device
(see notes given in the documentation for the standard device).
BS
Green
Signalling according
to DR303−3
CANopen state ("Z")
BE
Red
CANopen error ("F")