Technical data
General data and operating conditions
3
l
55
EDK94AMH24 DE/EN/FR/ES/IT 3.1
3
Technical data
3.1
General data and operating conditions
Supply system data
Supply forms
With earthed neutral Unrestricted use
IT systems
Observe instructions about special measures!
Noise emission
EN 61800−3
Cable−guided: cannot be specified because dependent on the
conditions present in the interconnected system
Radiation: category C3
Noise immunity
EN 61800−3
Category C3
Conformity and approval
Conformity
CE
2006/95/EC
Low−voltage directive
Approval
UL
UL 508C
Power Conversion Equipment, File No. 132659
GOST−R
51321.1−2000
51321.3−99
No. POCC DE.AN30.B08815
Protection of persons and devices
Enclosure
EN 60529
IP 20
Not in the wire range of
the terminals on the
motor side
NEMA 250
Protection against contact in
accordance with type 1
Insulation resistance
EN 61800−5−1
Overvoltage category III
Reduction from 2000 m amsl onwards: Overvoltage category
II
Insulation of control
circuits
EN 61800−5−1
Safe mains isolation by double/reinforced insulation for
mains with neutral earthing with a rated voltage for the
external conductor/star point up to 300 V.
Short−circuit strength
EN 61800−5−1
Motor connection: with restrictions, error acknowledgement
required
Control connections: without restrictions
Motor − protective
measures against
l
Short circuit
l
Earth fault
l
Overvoltage
l
Motor stalling
l
Motor overtemperature
(PTC or thermal contact, I
2
t monitoring)
Discharge current
EN 61800−5−1
> 3.5 mA AC, > 10 mA DC
Observe regulations and
safety instructions!
Cyclic mains switching
Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.