Maintenance 4 4 maintenance, 1 replacing the battery, 2 replacing a connector board – Lenze EZAEDE1000 User Manual
Page 29
EZAEDE1000 DE/EN/FR/IT/ES 1.1
15
Maintenance
4
4
Maintenance
4.1
Replacing the Battery
Refer to Section 3.1.
4.2
Replacing a Connector Board
The memory module connector boards can be replaced by a customer. The spare
connector board (p/n EZAEDB001) includes one connector board. When connectors
have been damaged or worn out by usage, a fault will occur in the copy process. If
this happens repeatedly, it is time to replace the connector board. Depending on
usage, the user may wish to replace just one or both connector boards. If a master
is typically inserted for each copy made, then replace both boards. If multiple copies
are made from each master inserted, try replacing only the slave connector board. If
problems persist, replace the master connector board.
1. To replace a connector board, turn the Memory Module Copier over.
2. Pull the two recessed clips toward the center of the back cover and lift off back cover.
+
-
STOP!
Circuit boards are sensitive
to Electro-Static Discharge.
Follow proper ESD protocol
when cover is removed.
UP
Not at an angle
3. Remove the battery to prevent the MMC from inadvertently starting.
4. Remove left and/or right connector board by pulling straight up. Do not twist or
pull at an angle. It may damage the connectors. Replace with new connector board.
5. Put battery back in.
6. Replace back cover. Make sure hinged clips click into place.