Operation 3 – Lenze EZAEDE1000 User Manual
Page 25
EZAEDE1000 DE/EN/FR/IT/ES 1.1
11
Operation
3
POWER LED
STATE
LED Description
State Description
Red
Green
NOTE: MMC = Memory Module Copier
m
m
Both Off
No power
m
Red: slow flash/3 sec; Green: Off
MMC Off; Battery Charging - USB charger connected
m
Red: Off; Green: slow flash/3 sec
MMC Off: Battery Charged - USB charger connected
m
Red: Off; Green On
MMC On; Battery charged or Battery operation
Red: slow flash/3 sec; Green: On
MMC On; Battery charging
Alternating: Red: flash; Green:
flash
MMC On; Battery error: Battery over-charged or temperature
too high
Green: On 7 sec then 2 flashes
R & G
MMC On, Low Battery Warning
MASTER LED
STATE
LED Description
State Description
Red
Green
m
m
Both Off
No memory module in the Master socket
m
Red: Off; Green: On
Memory module inserted in Master socket; Successful
Copy if Slave =
m
Red: Off; Green: double flash
synchronized with Slave
Copying in progress
m
Red: On or double flashing; Green Off
Copy operation failed. Refer to the error code table.
SLAVE LED
STATE
LED Description
State Description
Red
Green
m
m
Both Off
No memory module in the Slave socket
m
Red: Off; Green: slow flash
Memory module inserted in Slave socket
m
Red: Off; Green: double flash synchronized
with Master
Copying in progress
m
Red: Off; Green On
Last Copy operation finished successfully
m
Red: On or double flashing; Green Off
Copy operation failed. Refer to the error code table.
ERROR CODES
STATE
LED Description
Error Description
Red
Green
m
Steady Green
No Error. Operation is successful
m
Single blink Red
Data incompatible
m
Two blinks Red
Memory module verification failed
m
Three blinks Red
Slave memory module different than master
1
m
Four blinks Red
Unknown module
m
Five blinks Red
Access to memory module failed/timeout
m
Steady Red
General access failure
1
For 9400 Series valid module combinations, refer to footnotes 1 and 2 in section 1, Introduction.