beautypg.com

3operation, 3 lenze ac tech epm – Lenze EZAEDE1000 User Manual

Page 28

background image

14

EZAEDE1000 DE/EN/FR/IT/ES 1.1

3

Operation

3.5.2 9400 Series Memory Module

9400 Type

Memory Module (EPM) Attributes

M1xx

M2xx

M3xx

M4xx

Data validity check

No

Drive parameters copied

Yes

Application copied

1

Yes

Timer information copied

2

Not Available

Fault history copied

No

Application retain data copied

Yes

Real-time clock copied

N/A

N/A

N/A

Yes

Target module is an exact copy of Master module.

No

3

1

All application data is copied. To activate the copied application in the target inverter, execute the
following procedure in the target inverter:

parameter 2 subindex 0: 32 -> will stop the old application
parameter 5 subindex 0: 1 -> will select the copied application for activation
parameter 2 subindex 0: 5 -> will activate the selected application
parameter 2 subindex 0: 7 -> will store this selection in device retain again

2

Timer information like Mains On Time, Run Time and additional service counter data are not part of the
memory module contents this data is retained in the inverter’s memory.

3

All 9400 memory modules have an ID-Tag memory with individual contents which cannot be copied.
Also, some parts of the NV-RAM are not copied.

3.5.3 Lenze AC Tech EPM

Lenze AC Tech Product Type

EPM Attributes

SCF

SCD

SCL

SCM

TCF

TML

TMD

SMD

SMV

8400

Baseline

8400

motec

940/941

PositionServo

Master EPM color

Black, blue or gray

Blue

Blue or gray

White

Target EPM color

Gray

1

Blue

Gray

1

White

2

Data validity check

Yes

3

Yes

3

Yes

3

Yes

3

Yes

3

Yes

3

Yes

3

No

4

Drive parameters copied

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Vector calibration
information copied

Not applicable

No

6

No

6

N/A

Yes

7

Yes

Yes

N/A

Timer information copied

8

Not applicable

No

No

No

No

Yes

No

N/A

Fault history copied

No

No

No

No

No

Yes

No

Yes

OEM area created

9

Yes

Yes

Yes

Yes

Yes

No

No

No

Target EPM is an exact
copy of Master EPM.

No

No

No

No

No

No

No

Yes

1 Gray EPM bulk pack(10) part number = EEPM2BA.
2 White EPM bulk pack (10) part number = EEPM2WA.
3 EPM validity checked prior to copying. An EPM that contains invalid data will not be copied.
4 No validity check is performed on EPM data. All EPM data is copied as is.
5 Drive parameters include all parameters listed in drive’s Operating Instructions and Communcations

Reference Guide manuals.

6 If the EPM is setup for vector speed or vector torque mode, then the drive in which the EPM is inserted will

have to be calibrated before it will be allowed to run.

7 Vector calibration information is only transferred for SMV drives with parameter versions 533 or 541.
8 Timer information includes the inverter’s Mains On Time and Run Time. It may include additional

information for specific models.

9 The OEM area contains settings specific to original equipment manufacturers. The data in this area can

ONLY be written to by the memory module copier.