3operation, 3 lenze ac tech epm – Lenze EZAEDE1000 User Manual
Page 28
14
EZAEDE1000 DE/EN/FR/IT/ES 1.1
3
Operation
3.5.2 9400 Series Memory Module
9400 Type
Memory Module (EPM) Attributes
M1xx
M2xx
M3xx
M4xx
Data validity check
No
Drive parameters copied
Yes
Application copied
1
Yes
Timer information copied
2
Not Available
Fault history copied
No
Application retain data copied
Yes
Real-time clock copied
N/A
N/A
N/A
Yes
Target module is an exact copy of Master module.
No
3
1
All application data is copied. To activate the copied application in the target inverter, execute the
following procedure in the target inverter:
parameter 2 subindex 0: 32 -> will stop the old application
parameter 5 subindex 0: 1 -> will select the copied application for activation
parameter 2 subindex 0: 5 -> will activate the selected application
parameter 2 subindex 0: 7 -> will store this selection in device retain again
2
Timer information like Mains On Time, Run Time and additional service counter data are not part of the
memory module contents this data is retained in the inverter’s memory.
3
All 9400 memory modules have an ID-Tag memory with individual contents which cannot be copied.
Also, some parts of the NV-RAM are not copied.
3.5.3 Lenze AC Tech EPM
Lenze AC Tech Product Type
EPM Attributes
SCF
SCD
SCL
SCM
TCF
TML
TMD
SMD
SMV
8400
Baseline
8400
motec
940/941
PositionServo
Master EPM color
Black, blue or gray
Blue
Blue or gray
White
Target EPM color
Gray
1
Blue
Gray
1
White
2
Data validity check
Yes
3
Yes
3
Yes
3
Yes
3
Yes
3
Yes
3
Yes
3
No
4
Drive parameters copied
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Vector calibration
information copied
Not applicable
No
6
No
6
N/A
Yes
7
Yes
Yes
N/A
Timer information copied
8
Not applicable
No
No
No
No
Yes
No
N/A
Fault history copied
No
No
No
No
No
Yes
No
Yes
OEM area created
9
Yes
Yes
Yes
Yes
Yes
No
No
No
Target EPM is an exact
copy of Master EPM.
No
No
No
No
No
No
No
Yes
1 Gray EPM bulk pack(10) part number = EEPM2BA.
2 White EPM bulk pack (10) part number = EEPM2WA.
3 EPM validity checked prior to copying. An EPM that contains invalid data will not be copied.
4 No validity check is performed on EPM data. All EPM data is copied as is.
5 Drive parameters include all parameters listed in drive’s Operating Instructions and Communcations
Reference Guide manuals.
6 If the EPM is setup for vector speed or vector torque mode, then the drive in which the EPM is inserted will
have to be calibrated before it will be allowed to run.
7 Vector calibration information is only transferred for SMV drives with parameter versions 533 or 541.
8 Timer information includes the inverter’s Mains On Time and Run Time. It may include additional
information for specific models.
9 The OEM area contains settings specific to original equipment manufacturers. The data in this area can
ONLY be written to by the memory module copier.