beautypg.com

Electrical data, Technical data, 2 electrical data standard device – Lenze CPC 2800 Operating Instructions User Manual

Page 24: Acu ups control unit (option)

background image

Technical data

Electrical data

4

l

24

BA_CPCx8xx EN 3.0

Permissible ambient temperatures for systems with "Smart Cool" cooling

Standard device

l

With standard
hard disk

l

With hard disk for
continuous
operation (24/7)

1)

l

With hard disk for
extended
temperature
range

l

Up to 1 GB RAM

l

With CF card

l

With DVD writer
drive

Processor

[°C]

Intel

â Coreä Duo

1.66 GHz at max.
50 % CPU utilisation

2)

5 ... 45

5 ... 45

0 ... 45

5 ... 40

Intel

â Coreä Duo

1.66 GHz at max.
100 % CPU
utilisation

2)

5 ... 40

5 ... 40

0 ... 40

5 ... 40

1)

We recommend replacing the hard disk after 30,000 operating hours or after 5 years.

2)

The CPU utilisation can be determined via the Windows task manager (register "System performance")

4.2

Electrical data

Standard device

Supply

Voltage

Current at 24 V

1)

Fuse

Buffer battery

Intel

â

Core

Duo

ä

Intel

â

Atom

ä

Type

Type

Service life

[V DC]

[A]

[A]

[years]

CPC 2800

24 (+18 ... 30)

2)

1.4

0.8

^ 35

^ 34

> 6 (25 °C)

1)

Without ACU UPS control unit, DVD−Drive, MC card, and USB consumer

2)

With ACU UPS Control Unit DC +20 ... 30 V

ACU UPS control unit (option)

Type

Operating voltage

Max. current

Charging current in operating

range

[V DC]

[mA]

[mA]

At 5 V

At 12 V

ACU UPS

12 / 5

10

10 ... 600

1)

Approx. 250

1)

Subject to charging