Fuse change, Maintenance, Stop – Lenze CS9800 Operating Instructions User Manual
Page 57: Repair fuse change, 3 fuse change

Maintenance
Repair
Fuse change
l
57
BA_CSx8xx EN 3.0
8.3.3
Fuse change
(
Stop!
Damage of the device by non−permissible fuse possible
The baseboard in the device is protected by a fuse which will be damaged if
the supply voltage applied is too high.
Possible consequences:
ƒ
The device can be damaged if a non−approved fuse is installed.
Protective measures:
ƒ
The fuse may only be replaced by an approved type.
Approved types:
ƒ
Littelfuse 0454 004
CA
N2
CA
N2
CA
N1
MC-
POWER
FAN2
FAN3
CF-CARD
RESET
USB
-μCON
BL
IG
HT
ACCU
CR2450
1
2
19
20
F1
T4A
0
ELx7xx−018
How to proceed:
1. Remove the MC Card, if inserted.
2. Remove the old fuse
0 from the support.
3. Insert a new approved fuse
0 into the support.