Technical data
General data and operating conditions
l
27
BA_CSx8xx EN 3.0
Operating conditions
Mounting conditions
Mounting place
Stand−alone operator console for support arm mounting or
direct fixing to a wall, protected against direct solar radiation
Ambient conditions
Climatic
Storage
−10 ... +60 °C
Transport
−10 ... +60 °C
Operation
Depending on the equipment (
^ 27)
Relative humidity
10 ... 90 %, non−condensing
Site altitude
StoragetTransport
< 12000 m amsl
Operation
< 3000 m amsl
Chemical resistance
Decor film
DIN 42115
Touch/display
Mechanical load capacity
Decor film
DIN 42115
max. 100 N
Touch/display
Switching element
)
Note!
The failure probability of an electronic component increases with the ambient
temperature to which the component is subjected. Regarding the
serviceability and reliability, particular attention should be paid to the cooling
of the device. For every application, you should take care to keep the heating
of the device as low as possible.
Permissible ambient temperatures
Standard device
l
With standard hard
disk
l
With hard disk for
continuous operation
(24/7)
1)
l
With hard disk for
extended temperature
range
l
Up to 1 GB RAM
l
With CF card
Processor
[°C]
Intel
â Atomä N270,
1.6 GHz
5 ... 40
5 ... 45
2)
0 ... 45
2)
1)
We recommend to replace the hard disk after 30 000 hours of operation or after five years at the latest.
2)
Systems in accordance with UL
: 0 ... 40
°C