Command station cs 5850, Operation, Controls and displays command station cs 5850 – Lenze CS9800 Operating Instructions User Manual
Page 50: Home, Pg dn, Pg up end status power fail, Is on when a power supply failure has occurred, Is lit if a power supply failure has occurred, Is lit when the supply voltage is present, Flashes

Operation
Controls and displays
Command Station CS 5850
l
50
BA_CSx8xx EN 3.0
7.2.3
Command Station CS 5850
Q
+
R
F1
F2
F5
-
S
T
F3
F4
@
\
Z
F11
F10
Y
X
F9
F8
F12
W
V
U
F7
F6
Shift
Alpha
Bs
Space
Enter
Esc
Del
Ins
Menu
Alt
Ctrl
Home
1
I
0
M
4
E
7
A
Pg Dn
*
3
J
K
L
/
,
N
O
P
Pg Up
End
Status
Power
Fail
2
.
+
6
F
G
H
-
9
B
C
D
5
8
6
7
9
2
1
0
4
3
CS57x0−024
Pos. Designation
Function
Standard mode
Alpha mode
Service mode
Switch on mode:
Press "alpha key" (LED is on)
Press "menu key"
Switch off mode:
Press "alpha key" (LED is off)
Press "menu key" or wait for
35 s
0 Display
Application−dependent
1 Status LEDs
Power (green):
l
Is ON when the supply voltage is present.
Fail (red):
l
Is ON when a power supply failure has occurred
l
Is blinking when the screen signal is missing.
Status (yellow):
l
Indicates access to a storage medium.
2 Function keys F1 ... F12: Send key code for
Shift−F1 ... Shift−F12
F1 ... F12: Send key codes for
"Q" ... "@"
Tool: Application−dependent
+: Increase screen brightness
−: Reduce screen brightness
3 Reset button Reset PC (restart)
4 Status LEDs
Error (red):
l
Is lit if a power supply failure has occurred;
l
Is blinking when the screen signal is missing.
HD (yellow):
l
Indicates access to a storage medium.
Power (green):
l
Is lit when the supply voltage is present.
l
Flashes (
−−−
−
−−−
−
) in the case of a hardware error.
l
Is blinking (
−−
−
−−
−
) when the ACU UPS (optional) is being charged.
l
Is blinking (
−−
−−
−−
−−
) when there is a supply voltage failure and the device is being supplied
by the ACU UPS.
l
Is blinking (
−
−
−
−
) when the supply voltage of the ACU UPS is too low (e.g. rechargeable
battery is empty or missing).
l
Blinks 4 x per second if the ACCU−PACK causes a short circuit or if the CAPS−PACK is
completely discharged.
6 Numeric
keypad
Send key codes for "0" ... "9"
and calculation operators
Send key codes for "A" ... "P"
Functionality same as in
standard/alpha mode
7 Cursor keys
Without "Shift" key: Move cursor/marker in steps and set
tab
With "Shift" key: Move cursor/marker to the beginning/end
or page by page
Functionality same as in
standard/alpha mode
9 Control keys
Standard functions of a MF2 keyboard
(For "alpha" and "menu" see "Switch on/off mode")
Functionality same as in