Chapter, Installation – Koolance ERM-3K3UC-R User Manual
Page 9
10
11
User Manual
Positioning the ERM
The ERM-2K3U is designed to operate in 3 different orientations. The display can
be rotated by gently pulling forward on the display and rotating it into place. (NOTE:
horizontal orientations may require more coolant to be added for the reservoir.)
Aluminum Post Feet
Steel Bracket Feet
Display Right - OK!
Display Left - OK!
Display Top -
OK!
Display Bottom -
NO!
For horizontal orientations, aluminum post feet and rubber foot pads are included.
These are screwed into one of the side panels. Be sure to use these for proper
airflow clearance when the unit is placed horizontally (and not rack mounted)!
For vertical orientations, steel bracket feet are included. These are attached to the
bottom side of the cooling unit with the same screws used for the rack mounting
ears.
If the cooling system can not be placed adjacent to the computer, it can be moved
farther away. Depending on heat load, 5-10 feet (1.5-3 meters) should be an
acceptable distance for most cooling systems. Extra tubing can be purchased from
Koolance.com or your local reseller.
Installation
Chapter
2
Installation