Erm-3k3u system diagram, Display panel – Koolance ERM-3K3UC-R User Manual
Page 5
2
3
User Manual
ERM-3K3U System Diagram
Reservoir
Radiator
(Primary Heat Exchanger)
Radiator -
The primary heat exchanger is the main cooling element, and provides
high thermal dissipation in a relatively small area. Inside, louver fins are webbed
between flat horizontal liquid pipes.
Reservoir & Pump -
The coolant tank is transparent for easy liquid-level monitoring
through the front window. It is filled through a small metal fill port on top. The white
reservoir LED illumination can be toggled via the front button.
Pump
Liquid Outlet
Liquid Inlet
DC Signal and Sensors
Reservoir Illumination Button
AC Power Plug
Power
Button
System Features
Display Panel
CAUTION:
This cooling system allows full user control of hardware
safety settings, such as audio alarm, shutdown, and pump speed.
Please be sure to configure your Display Panel properly, or damage
to your computer, data, and/or equipment could result.
!
The Koolance display panel allows control and
monitoring of various aspects of the cooling
unit. 4 buttons are used, with directional
arrows to navigate or change settings, and a
center button to enter/exit.
• On the main screen, hold
◙
for 3 seconds to change display units between
ºC/ºF and LPM/GPM.
• You can exit any menu and return to the main screen by holding
◙
for 2
seconds.
• To reset ALL settings to default, hold ▼ + ▲ for 5 seconds.
Main Menu
To enter the main menu, briefly press
◙
. The selected option will begin flashing.
Use ▼ and ▲ to navigate this menu.
TEMP SET: Temperature, alarm, and shutdown settings
FAN SET: Fan settings
PUMP SET: Pump settings
FLOW SET: Flow meter settings
DISPLAY SET: Display settings
When in the top menu, press
◙
to enter one of the above categories. To exit from
here, press ◄.
TEMP SET
The temperature menu allows configuration of the alarm and safety shutdown
options. This cooling
system can monitor up to 3 (included) temperature sensors.
An audio alarm will sound if any sensor reaches its set alarm point. The offending
sensor will also flash in the display, and the radiator fans and pump will increase
Navigate Up,
Increase Setting
Navigate Down,
Decrease Setting
Navigate
Left
Navigate
Right
Enter/Exit
◙
▲
▼
NOTE:
After powering on this unit, wait
5 seconds before powering it off again.
Otherwise, the display may lock-up
and require reset (hold ▼ + ▲ for 5
seconds.)