English – Klein Tools CL100 User Manual
Page 3
ENGLISH
AUTO
A
AC
PRESS
TO SELECT
Diode
Continuity
AUTO
A
AC
AUTO
A
AC
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
200mV
0.1mV
± (0.8% + 2 digits)
2V
0.001V
20V
0.01V
200V
0.1V
600V
1V
± (1.0% + 2 digits)
Overload Protection:
•
200mV range:
250V DC / AC RMS
•
2V-600V ranges:
600V DC / AC RMS
Input Impedance:
10M
Ω.
AC Voltage Measurement
Range
Resolution
Accuracy
200mV
0.1mV
± (1.0% + 10 digits)
2V
0.001V
± (1.0% + 5 digits)
20V
0.01V
200V
0.1V
600V
1V
± (1.5% + 5 digits)
Overload Protection:
•
200mV range:
250V DC / AC RMS
•
2V-600V ranges:
600V DC / AC RMS
Input Impedance:
10M
Ω
Response:
Averaging
AC Current Measurement
Range
Resolution
Accuracy
2A
0.001A
± (3.5% + 20 digits)
≤
0.5A
2A
0.001A
± (3.0% + 10 digits)
>
0.5A
20A
0.01A
± (3.0% + 10 digits)
200A
0.1A
± (2.5% + 10 digits)
600A
1A
± (1.5% + 5 digits)
Frequency Range:
50 to 60Hz
Response:
Averaging
Resistance Measurement
Range
Resolution
Accuracy
200
Ω
0.1
Ω
± (1.2% + 2 digits)
2k
Ω
0.001k
Ω
20k
Ω
0.01k
Ω
200k
Ω
0.1k
Ω
2M
Ω
0.001M
Ω
20M
Ω
0.01M
Ω
± (2.0% + 5 digits)
Overload Protection:
250V
Open Circuit Voltage:
0.25V
• Do not measure resistance on a live circuit.
3.
Diode / Continuity
Diode Features:
HOLD
Display shows:
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
4. Resistance:
< 20MΩ
Features:
HOLD
RANGE
Continuity Features:
HOLD
• Display shows resistance.
• Buzzer sounds if less than 60
Ω.
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
MAX
Maximum Reading
Low Battery
AUTO
Auto Range Active
H
Hold Active
A
Current in Amps
V
Voltage Measurement
Diode Test
Ω
Resistance in Ohms
Continuity Test
m
Milli 10
-3
k
Kilo 10
M
Mega 10
6