Klein Tools MM6000/6000N User Manual
Mm6000, Instruction manual
ENGLISH
Instruction
Manual
ENGLISH
MM6000
• true rMs
• auto / Manual
RANGE
• auto HolD
• MaX / Min
• Bar GrapH
• BacKlit DisplaY
• 3-5/6 DiGit
6000 count lcD
• leaD storaGe
4007036
sYMBols useD on lcD
~
ac Measurement
Dc Measurement
-
negative Dc Value
AT
auto range active
O.L.
overload: range exceeded
Apo
auto power-off active
low Battery
HolD
Hold active
MIN
Minimum reading
MAX
Maximum reading
%
Duty cycle Mode
Frequency Mode
V
Voltage Measurement
A
current in amps
Ω
resistance in ohms
Diode test
F
capacitance in Farads
continuity test
relative / Zero Mode
n
nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
°F
Degrees Fahrenheit
°C
Degrees celsius
A- HOLD
auto-Hold active
LOW
Z
low impedance
electrical speciFications
Dc Voltage Measurement
range
resolution
accuracy
600mV ˜ 600V
0.1mV ˜ 0.1V
± (0.2% + 5 digits)
1000V
1V
± (0.5% + 10 digits)
overload protection:
1000V
input impedance (nominal)
: >10MΩ, <100pF
input impedance (loW Z)
: >3kΩ, <200pF, up to 600V RMS
ac Voltage Measurement
range
resolution
accuracy
40Hz ~ 400Hz
accuracy
400Hz ~ 2kHz
600mV
0.1mV
± (0.75% + 5 digits)
± (2.5% +10 digits)
6V ~ 600V
1mV ~ 0.1V
± (2.0% + 8 digits)
1000V
1V
± (0.75% + 8 digits)
± (2.0% +8 digits)*
Continued on next page.
overload protection:
1000V RMS
input impedance (nominal):
>10MΩ, <100pF
input impedance (loW Z)
: >3kΩ, <200pF, up to 600V RMS
Frequency response:
40 to 2kHz
response:
True RMS
*Accuracy for 400Hz ~ 1kHz range only.
Dc current Measurement
range
resolution
accuracy
600μA ~ 400mA
0.1μA ~ 0.1mA
± (1.0% + 5 digits)
6A ~ 10A
1mA ~ 10mA
± (1.5% + 5 digits)
overload protection: µama: 400mA (F440mA/1000V fuse) / a input: 10A (F11A/1000V fuse)
ac current Measurement
range
resolution
accuracy
40Hz ~ 2kHz
600μA ~ 400mA
0.1μA ~ 0.1mA
± (1.2% + 5 digits)
6A ~ 10A
1mA ~ 10mA
± (1.8% + 5 digits)
overload protection: µama: 400mA (F440mA/1000V fuse) / a input: 10A (F11A/1000V fuse)
Frequency:
40 to 2kHz
response:
True RMS
resistance Measurement
range
resolution
accuracy
600
Ω ˜ 6MΩ
0.1
Ω ˜ 0.001MΩ
± (1.0% + 5 digits)
50M
Ω
0.01M
Ω
± (1.5% + 10 digits)
overload protection:
600V RMS
capacitance Measurement
range
resolution
accuracy
60nF
0.01nF
± (3.5% + 6 digits)
600nF ~ 6000μF
0.1nF ~ 1μF
overload protection:
600V RMS
Frequency Measurement
range
resolution
accuracy
99.99Hz ˜ 399.9kHz
0.01Hz ˜ 0.1kHz
± (0.1% + 3 digits)
overload protection:
600V RMS
sensitivity:
2.5V RMS
Duty cycle Measurement
range
resolution
accuracy
1.0 ˜ 99.0%
0.1%
± (0.2% per kHz + 0.1% + 8 digits)
overload protection:
600V RMS
Sensitivity: < 50V RMS
Frequency range:
0.5Hz to 10kHz
Diode test
overload protection
range
test current
open circuit Voltage
600V RMS
6.0V DC
0.25mA
< 1.8V DC
continuity test
overload protection
open circuit Voltage
threshold (appx.)
600V RMS
< 0.44V
<40
Ω
temperature Measurement
range
resolution
accuracy
-58 ~ 600°F
0.1°F
± (1.0% + 5.4°F)
-50 ~ 600°C
0.1°C
± (1.0% + 3.0°C)
600 ~ 1832°F
1°F
± (1.0% + 5.4°F)
600 ~ 1000°C
1°C
± (1.0% + 3.0°C)
overload protection:
600V RMS
K-type
thermocouple accuracy:
Not specifi ed
Specifi cations subject to change.
WarrantY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifi cations section, allow the instrument to return to normal operating
conditions before using it.
Disposal / recYcle
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations.
Prior to disposal of this product, please contact Klein Tools
for proper disposal options.
custoMer serVice
Do not apply voltage to thermocouple.
• Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000°C).
8.
temperature:
Features:
MaX/Min
REL
HolD
testing Fuse:
• When selecting uA or mA/A functions the meter will indicate
“lead” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
Klein tools, inc.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
Rev 04/14 B
139750
7.
Frequency (Hz) / Duty cycle: <400kHz
Features:
HolD
6.
low impedance (loW Z): < 600V
Do not use (loW Z) mode at voltages greater than 600V.
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• See AC/DC Voltage instruction.
Capacitance Features:
HolD
safely discharge capacitor before
measurement.
• Reading may take up to 60 seconds
for large capacitors.
auto HolD
1000V
10A
Dwg Name:
MM6000-139750ART Dwg No: 139750
ECO No:
016671 Pkg Dwg Ref: 1650 Rev: B
Color Reference:
CEN-PACK-003-A
MM6000-139750ART-Instructions.indd 1-4
5/5/14 10:19 AM