Klein Tools CL2500 User Manual
Instruction manual, Cl 2500
cuStOMER SERVIcE
KLEIN tOOLS, INc.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
139677 Rev. 11/13 B
ENGLISH
• 1000A Ac/Dc
• tRuE RMS
• AutO / MANuAL
RANGE
• NON cONtAct
VOLtAGE tEStER
• MAX / MIN / HOLD
• ANALOG BAR GRApH
• 3-5/6 DIGIt
5999 cOuNt LcD
• BAcKLIGHt
• WORKLIGHt
ENGLISH
8.
Non contact Voltage (NcV): > 25V Ac
SYMBOLS uSED ON LcD
~
Ac Measurement
Dc Measurement
-
Negative Dc Value
AT
Auto Range Active
O.L.
Overload: Range Exceeded
Apo
Auto power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
MAX
Maximum Reading
%
Duty cycle Mode
Frequency Mode
V
Voltage Measurement
A
current in Amps
Ω
Resistance in Ohms
Diode test
F
capacitance in Farads
continuity test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELEctRIcAL SpEcIFIcAtIONS
Dc Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 600V
0.1mV ˜ 0.1V
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload protection:
1000V
Ac Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 750V
0.1mV ˜ 1V
± (2.0% + 5 digits)
Overload protection:
750V RMS
Frequency Response:
45 to 400 Hz
Minimum Voltage for Frequency Measurement:
200mV
Response:
True RMS
Dc current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (1.2% + 3 digits)
2000µA
1µA
60A
0.01A
± (2.5% + 15 digits)
600A ~ 1000A
0.1A ~ 1A
± (1.5% + 8 digits)
Overload protection:
•
Voltage:
600V RMS
•
current:
2000µA (leads), 1000A (clamp)
Ac current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (2.0% + 5 digits)
2000µA
1µA
± (1.5% + 5 digits)
60A
0.01A
± (2.9% + 15 digits)
600A ~ 1000A
0.1A ~ 1A
± (1.9% + 8 digits)
Overload protection:
•
Voltage:
600V RMS
•
current:
2000µA (leads), 1000A (clamp)
Frequency:
45 to 400Hz
Minimum current for Frequency Measurement:
400µA (leads) or 20A (clamp)
Response:
True RMS
Resistance Measurement
Range
Resolution
Accuracy
600
Ω ˜ 6MΩ
0.1
Ω ˜ 0.001MΩ
± (1.0% + 4 digits)
60M
Ω
0.01M
Ω
± (2.0% + 4 digits)
Overload protection:
600V RMS
capacitance Measurement
Range
Resolution
Accuracy
60nF ˜ 6000µF
0.01nF ˜ 1µF
± (3.5% + 6 digits)
Overload protection:
600V RMS
Frequency Measurement
Range
Resolution
Accuracy
99.99Hz ˜ 499.9kHz
0.01Hz ˜ 100Hz
± (0.1% + 4 digits)
Overload protection:
600V RMS
Duty cycle Measurement
Range
Resolution
Accuracy
0.1 ˜ 99.9%
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
Overload protection:
600V RMS
Diode test
Overload protection
Range
test current
Open circuit Voltage
600V RMS
6.0V
Appx. 0.25mA
< 1.8V DC
continuity test
Overload protection
Open circuit Voltage
threshold (Appx.)
600V RMS
< 0.44V
~40
Ω
Non contact Voltage Detector
On Voltage
Appx. 25V AC and above
WARRANtY
www.kleintools.com/warranty
cLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
StORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISpOSAL / REcYcLE
caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
750V
1000V
1000A
Dwg Name:
CL2500-139677ART Dwg No: 139677
ECO No:
14678 Pkg Dwg Ref: 1650 Rev: B
Color Reference:
CEN-PACK-003-A
Instruction Manual
CL
2500
CL2500 Instruction Manuals - MASTER.indd 1-4
11/20/2013 2:57:08 PM