Klein Tools MM1300 User Manual

Instruction manual, Mm 1300

background image

cuStoMEr SErVIcE

KLEIN tooLS, INc.

450 Bond Street

Lincolnshire, IL 60069

1-877-775-5346

[email protected]

www.kleintools.com

139713 Rev. 03/14 B

ENGLISH

Instruction Manual

• auto /

MaNuaL
raNGE

• auto HoLD

• MaX / MIN

• Bar GrapH

• BacKLIGHt

• LEaD

HoLDEr

• 3-5/6 DIGIt

6000 couNt
LcD

ENGLISH

8. temperature:

Features:

SYMBoLS uSED oN LcD

~

ac Measurement

Dc Measurement

-

Negative Dc Value

AT

auto range active

O.L.

overload: range Exceeded

Apo

auto power-off active

Low Battery

HoLD

Hold active

MIN

Minimum reading

MAX

Maximum reading

%

Duty cycle Mode

Frequency Mode

V

Voltage Measurement

A

current in amps

Ω

resistance in ohms

Diode test

F

capacitance in Farads

continuity test

relative / Zero Mode

n

Nano 10

-9

µ

Micro 10

-6

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

°F

Degrees Fahrenheit

°C

Degrees celsius

a-HoLD

auto-Hold active

ELEctrIcaL SpEcIFIcatIoNS

Dc Voltage Measurement

range

resolution

accuracy

600mV ˜ 600V

0.1mV ˜ 0.1V

± (0.5% + 4 digits)

1000V

1V

± (0.8% + 10 digits)

overload protection:

1000V

Input Impedance (Nominal): 10MΩ, <100pF

ac Voltage Measurement

range

resolution

accuracy

600mV

0.1mV

± (0.75% + 5 digits)

6V ~ 600V

1mV ~ 0.1V

1000V

1V

± (1.0% + 8 digits)

overload protection:

1000V RMS

Input Impedance (Nominal): 10MΩ, <100pF

Frequency response:

40 to 400 Hz

response:

Averaging

Dc current Measurement

range

resolution

accuracy

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.0% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (1.5% + 5 digits)

overload protection:

µama:

F440mA/1000V fuse

a Input:

F11A / 1000V fuse

ac current Measurement

range

resolution

accuracy

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.5% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (2.0% + 5 digits)

overload protection: µama:

F440mA/1000V fuse /

a Input:

F11A / 1000V fuse

Frequency:

40 to 400Hz

response:

Averaging

resistance Measurement

range

resolution

accuracy

600

Ω ˜ 6MΩ

0.1

Ω ˜ 0.001MΩ

± (1.0% + 5 digits)

60M

Ω

0.01M

Ω

± (1.5% + 10 digits)

overload protection:

600V RMS

capacitance Measurement

range

resolution

accuracy

60nF

0.01nF

± (3.5% + 6 digits)

600nF ~ 6000µF

0.1nF ~ 1µF

overload protection:

600V RMS

Frequency Measurement

range

resolution

accuracy

99.99Hz ˜ 499.9kHz

0.01Hz ˜ 0.1kHz

± (0.1% + 3 digits)

overload protection:

600V RMS

Sensitivity:

>0.7V RMS

Duty cycle Measurement

range

resolution

accuracy

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

overload protection:

600V RMS

Sensitivity:

< 50V

Frequency range:

<10kHz

Diode test

overload protection

range

test current

open circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC (typ.)

continuity test

overload protection

open circuit Voltage

threshold (appx.)

600V RMS

< 0.44V

<40

Ω

temperature Measurement

range

resolution

accuracy

-58 ~ 600°F

0.1°F

± (1.0% + 5.4°F)

-50 ~ 600°C

0.1°C

± (1.0% + 3.0°C)

600 ~ 1832°F

1°F

± (1.0% + 5.4°F)

-600 ~ 1000°C

1°C

± (1.0% + 3.0°C)

overload protection:

600V RMS

thermocouple accuracy:

Not specified

Specifi cations subject to change

7. capacitance:

< 6000µF

Features:

HoLD

Safely discharge capacitor before measurement.

• Reading may take up to 60 seconds for large capacitors.

Do Not apply voltage to thermocouple.

• -58° to 1832°F (-50° to 1000°C)

testing Fuses:

• When selecting µA or mA/A functions the meter will indicate

LEad” if the test leads are not properly connected to the meter.

• Note: This message remaining on the screen after properly

connecting the test leads is an indication that the fuse is open.

MaX/MIN

HoLD

rEL

a- HoLD

6.

Frequency (Hz) / Duty cycle <500kHz
Features:

HoLD

WarraNtY

www.kleintools.com/warranty

cLEaNING

Clean the instrument by using a damp cloth. Do not use abrasive cleaners

or solvents.
Take care to keep the sensor lens clean at all times. Clean the lens using a soft

cloth or cotton swab with water or rubbing alcohol only, and allow the lens to

dry before use.

StoraGE

Remove the batteries when instrument is not in use for a prolonged period of

time. Do not expose to high temperatures or humidity. After a period of storage

in extreme conditions exceeding the limits mentioned in the Specifications

section, allow the instrument to return to normal operating conditions before

using it.

DISpoSaL / rEcYcLE

Do not place equipment and its accessories in the trash. Items

must be properly disposed of in accordance with local regulations.