Customer service, Warranty, Cleaning – Klein Tools CL1100 User Manual
Page 8: Storage, Disposal / recycle
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
139660
WARRANTY
See www.kleintools.com, contact Klein Tools at 1-877-775-5346, or visit a
distributor for warranty information.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifi cations
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
Duty Cycle Measurement
Range
Resolution
Accuracy
0.1 ˜ 99.9%
˜˜
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection:
600V RMS
Diode Test
Overload Protection Range Test Current
Open Circuit Voltage
600V RMS
2.0V
Appx. 0.25mA
< 1.6V DC
Continuity Test
Overload Protection
Open Circuit Voltage
600V RMS
< 0.44V
Temperature Measurement
Range
Resolution
Accuracy
-22°~14°F (-30°~-10°C)
0.1°F (0.1°C)
±5.4°F (±3.0°C)
15°~752°F (-9°~400°C)
0.1°F (0.1°C)
±(1.0% + [3.6°F or 2.0°C])
Overload Protection:
30V RMS
Non Contact Voltage Detector
On Voltage
Appx. 25V AC