ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
400mV ˜ ˜ 400V
0.1mV ˜ ˜ 0.1V
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload Protection:
1000V
AC Voltage Measurement
Range
Resolution
Accuracy
400mV ˜ ˜ 750V
0.1mV ˜ ˜ 1V
± (2.0% + 5 digits)
Overload Protection:
750V RMS
Frequency Response:
40 to 400 Hz
Minimum Voltage for Frequency Measurement:
200mV
Response:
Averaging
DC Current Measurement
Range
Resolution
Accuracy
400µA
0.1µA
± (1.2% + 3 digits)
2000µA
1µA
Overload Protection:
•
Voltage:
600V RMS
•
Current:
2000µA
AC Current Measurement
Range
Resolution
Accuracy
400µA
0.1µA
± (2.0% + 5 digits)
2000µA
1µA
± (1.5% + 5 digits)
40A
0.01A
± (2.9% + 15 digits)
400A
0.1A
± (1.9% + 8 digits)
Overload Protection:
•
Voltage:
600V RMS
•
Current:
2000µA
Frequency:
45 to 400Hz
Minimum Current for Frequency Measurement:
400µA or 20A
Response:
Averaging
Resistance Measurement
Range
Resolution
Accuracy
400
Ω
˜ 4M
˜˜
Ω
0.1
Ω
˜ 0.001M
˜˜
Ω
± (1.0% + 4 digits)
40M
Ω
0.01M
Ω
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Capacitance Measurement
Range
Resolution
Accuracy
40nF ˜ 4000µF
˜˜
0.01nF ˜ 1µF
˜˜
± (3.5% + 6 digits)
Overload Protection:
600V RMS
Frequency Measurement
Range
Resolution
Accuracy
99.99Hz ˜ 499.9kHz
˜˜
0.01Hz ˜ 0.1kHz
˜˜
± (0.1% + 4 digits)
Overload Protection:
600V RMS
Sensitivity:
1.8V RMS