Relay outputs

Quantity

2 relay outputs for basic type 902931/30

Relay

N/O contact configurable as N/C contact

Switching capacity

Up to 3 A at AC 230 V resistive load

Contact life

150,000 operations at 3 A / AC 230 V resistive load
350,000 operations at 1 A / AC 230 V resistive load
310,000 operations at 1 A / AC 230 V and cos phi > 0.7

Electrical isolation

Relay to analog outputs and interface; test voltage AC 3700 V (reinforced insulation)
Relay to relay; test voltage AC 2300 V (basic insulation)
Combined operation of mains voltage AC 230 V and SELV or PELV voltage
is not admissible due to the basic insulation between the relays.

Electrical data

Voltage supply

AC 110 to 240 V +10/-15 %, 48 to 63 Hz or AC/DC 20 to 30 V, 48 to 63 Hz

Power consumption

12 VA

Electrical connection

Screw terminals up to 2.5 mm

2

Electrical safety

According to DIN EN 61010, part 1
overvoltage category III,
pollution degree 2,
for installation into a control cabinet according to DIN EN 50178

Electrical isolation

The voltage supply is electrically isolated from the analog outputs, relays, and interfaces.

Test voltage

AC 3700 V

Environmental influences

Ambient temperature range

-20 to +50 °C without condensation (even with close mounting)

Storage temperature range

-30 to +70 °C

Temperature influence

±0.005 %

1

/K; per K deviation from the reference temperature 22 °C (±3 K)

Resistance to climatic conditions

Rel. humidity

85 % without condensation according to DIN EN 60721-3-3 3K3

Vibration resistance

Max. 1 g at 10 to 55 Hz according to DIN IEC 60068-2-6

EMC
- Interference emission
- Interference immunity
- Radio frequency spectrum

DIN EN 61326-1
Class A - only for industrial use -
Industrial requirements
ETSI EN 300 220-1 and ETSI EN 300 220-2

Case

Material

Polyamide

Flammability class

UL 94 V-2

Dimensions
With antenna screw connection (W × H × D)

22.5 mm × 115.0 mm × 117.8 mm

Installation

DIN rail 35 mm × 7.5 mm according to EN 60715

Protection type

IP20 according to DIN EN 60529

Installation position

Vertical

Weight

Approx. 200 g

Interfaces

1

All accuracy specifications in % from the measuring range end value of 20 mA or 10 V.