beautypg.com

Approvals technical data – JUMO 603021 Surface-Single Mounted Thermostat, ATH series Data Sheet User Manual

Page 2

background image

Data Sheet 603021

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

2014-01-08/00073225

Page 2/10

Approvals

Technical data

Control ranges and temperature probes

Capillary and temperature probe

Types

Switching function

DIN registry no.

Tests

You will find Declarations

of Conformity on

the Internet at:
www.jumo.net

➾ Products

➾ Thermostats

➾ Data sheet 603021

or they can be sent to you

upon request.

With rigid thermowell

With capillary

- DIN EN 14597
- Pressure Equipment

Directive 97/23/EC
(ATH.-20 and
ATH.-70 only)

ATHs-1

0

ATHf-1

0

TR

TR 891

ATHs-2

0

ATHf-2

0

TW

TW 892

ATHs-20

ATHf-20

STW (STB)

STW (STB) 894 S

ATHs-70

ATHf-70

STB

STB 895

Liquid-filled

Type

Control range / limit

value range

in °C

Max. allowable

probe temperature

in °C

Maximum

capillary length

in mm

Probe length, dimension "L" in mm

Probe ø "d" in mm, ø "6" = standard

6

8

ATH.-1
ATH.-2

-20 to +

0

50

-10 to +

0

40

+0

0 to +

0

50

+0

0 to +100

+20 to +

0

90

+20 to +120
+20 to +150
+30 to +110
+50 to +200
+50 to +250
+50 to +300
+50 to +350
+60 to +130

0

60

0

50

0

60

125
115
140
175
135
230
290
345
405
150

5000

141
185
185
107
138
106

0

88

125
101

0

73

0

63

0

53

135

0

92

115
115

0

75

0

91

0

75

0

65

0

84

0

72

0

54

0

49

- - -

0

90

ATH.-20
ATH.-70

+20 to +150
+30 to +110
+50 to +250
+50 to +300
+60 to +130

175
135
290
345
150

5000

0

77

108

0

64

0

55

116

60
75

0

49

- - -

79

Gas-filled

ATH.-1
ATH.-2

+20 to +400
+20 to +500
+20 to +500

460
575
575

1000
2000
4000

278
148
202

158

0

92

119

ATH.-20
ATH.-70

+20 to +400
+20 to +500
+20 to +500

460
575
575

1000
2000
4000

176
127
202

106

0

81

119

Type

Scale limit value

Capillary

Temperature probe

Comments

ATH.- . .

Up to 200 °C

Copper (Cu)

ø 1.5mm

Material-no. Cu-DHP

Copper (Cu)

Material-no. Cu-DHP

Hard soldered

Up to 350 °C

Copper (Cu)

ø 1.5mm

Material-no. Cu-DHP

Stainless steel (CrNi)

Material no. 1.4571

Hard soldered

Up to 500 °C

Stainless steel (CrNi)

ø 1.5mm

Stainless steel (CrNi)

Material no. 1.4571

Welded

Up to 350 °C

Stainless steel (CrNi)

ø 1.5mm

Stainless steel (CrNi)

Material no. 1.4571

Welded

Available at extra cost

Capillary length

1000 mm, max. 5000 mm as standard

Minimum bending
radius of the capillary

5 mm