6 Instrument description

6.1

Technical data

Ex marking

II 2G

Ex ed IIC T6

for potentially explosive gas atmospheres

II 2D

Ex tD A21 IP65 T80°C

for potentially explosive dust atmospheres

Explosion protection

II 2G

Equipment group II, Category 2,
equipment for potentially explosive gas atmospheres

II 2D

Equipment group II, Category 2,
equipment for potentially explosive dust atmospheres

Type of protection:
Ex ed IIC T6
Ex

General requirements
European Standard EN 60079-0

e

Increased safety
European Standard EN 60079-7

d

Flameproof enclosure
European Standard EN 60079-1

IIC

Gas group

T6

Temperature class

IP65 T80°C
Application in combustible dusts

European Standard

EN 61241-0
EN 61241-1

IP65

Protection to EN 60 529-IP65

T80°C

max. permissible surface temperature
(application in combustible dusts)

Test certificate

PTB 03 ATEX 1167

Permissible
ambient
temperature in
operation

Important note for installation and operation!

When evaluating the temperature relationships, the heat conduction must be
taken into account, as well as the max. permissible ambient temperaure and
the self-heating.

Capillary

Thermostat head

max.

+50°C

+50°C

min.

-20°C

-20°C