Warning – Hydrolevel 3200-Plus User Manual

Page 4

background image

4

WIRING

WARNING

Electrical shock hazard. To prevent electrical shock, death or equipment damage, disconnect power supply before
installing or servicing this control.

STEP 1

Connect 120 VAC Hot to terminal L1. Connect 120 VAC

Common to terminal L2. Disconnect means and overload

protection as required (provided by others).

STEP 3

Connect the circulator to C1-C2. (C2 is common.)

STEP 2

Connect the burner circuit to B1-B2. (B2 is common.)

STEP 4

Connect the thermostat to T/TV.

STEP 5

If the boiler is equipped with a plug-in style vent damper,

unplug the factory installed jumper from the receptacle on the

circuit board and replace it with the vent damper plug.

HydroStat 3200-Plus Instructions: HydroStat Instructions.8pg 11/14/13 3:34 PM Page 4