• Comply with

maximum permissible pressures at inlet and outlet and pressure

differences between inlet and outlet, see section ”Technical data”. Do not operate

the pump with overpressure at the inlet.

• Check that mains voltage and current conform with the equipment (see rating

plate).

• Avoid overpressure of more than 0.2 bar in case inert gas is connected to the

pump, the gas ballast or to a venting valve.

• Connect pipes gas tight at inlet and outlet of the pump.

Attention: Flexible elements tend to shrink when evacuated.

• Adopt suitable measures to avoid the flowing of liquids on or into the pump motor

when assembling or disassembling vacuum connections at the pump.

Risk of

corrosion and/or short circuit!

Check glass parts for damage and bracing.

Provide a firm level platform for the equipment and check that the system to be

evacuated is mechanically stable and that all fittings are secure. Ensure a stable po-

sition of the pump without any mechanical contact except of the pump feet. Comply

with all applicable safety regulations.

Keep a distance of minimum 20 cm between fan and ambient parts (e.g. housing,

walls, ...). Check fan regularly for dust/dirt, clean if necessary to avoid a cutback of

ventilation.

If the equipment is brought from cold environment into a room for operation, allow

the equipment to warm up (pay attention to water condensation on cold surfaces).

The diameter of the inlet and outlet pipeline should be at least as large as the diame-

ter of the pump connection pipelines.

Comply with all

applicable and relevant safety requirements (regulations and

guidelines),

implement the required actions and adopt suitable safety meas-

ures.

1.4 Ambient conditions

To the best of our knowledge the equipment is in compliance with the requirements

of the applicable EC-directives and harmonized standards (see ”Declaration of con-

formity”) with regard to design, type and model. Directive IEC 1010 gives in detail

conditions under which the equipment can be operated safely (see also IP degree

of protection).

Adopt suitable measures in case of differences, e. g. using the equipment outdoors,

installation in altitudes of more than 1000 m above mean sea level, conductive pol-

lution or bedewing.

Pay attention to the

permissible maximum ambient and gas inlet temperatures

(see ”Technical data”).

NOTICE

NOTICE

Ensure that the

coolant outlet pipeline of the condenser (accessory) is always

free and that it cannot get blocked. Install an optional coolant valve always in the

supply line of the exhaust waste vapor condenser only.

Secure coolant hoses at the hose nozzles (e.g. with hose clip) to prevent their

accidental slipping.

Check the overpressure safety relief device at the exhaust waste vapor conden-

ser in appropriate intervals.

This manual is related to the following products: