Fine tuning, Meanings of the lcd, 2 meanings of the lcd – GeoDesy Gigabit AF with auto failover User Manual
Page 17
GeoDesy Kft.
Telefon: 06-1-481-2050
Fax.: 06-1-481-2049
E-mail: [email protected]
http://www.geodesy-fso.com
17
6.1.3 Fine tuning
1. Site A start moving the
laserhead with the horizontal
fine adjustment screw by
looking at the Remote end
received level
2. Using the fine adjustment
screws, lighten as many LEDs
as possible
3.
Repeat step 1-2 on Site B.
4.
If necessary try step 1-2 on
both sites again.
6.2 Meanings of the LCD
Power: The head is powered up.
RX-OK: Received beam is good for communication.
TP Lk: Copper link between the head and the
Network equipment.
R-LS: The recived signal form the remote end is
modulated and .
RV/TLs: Remote end is visible for the management system and there is TP
connected to remote end
– same as TP-Lk but displays it on the remote end.
Please press the button and look at the LCD scren!
1.screen
Loc (local level):
Local Received level
Rem (remote level):
Remote
Sites Received level
Op-optimal
Ov-overload
REM:?FSO Currently on FSO channel searching the Remote side.
REM:?Backup Currently on Backup channel searching the Remote side.
REM:?FSO or Backup Auto Software desides on what to search for.
2.screen
HeadSN: Laser head serial number.
0000001
IP address: default IP address:192.168.100.220 or 192.168.100.221
After factory reset the IP address is always: 192.168.100.221
3.screen
4.screen
5.screen
Temperature
-AF mode position manual 000
-AF mode auto
Here shows that the auto fucus with is enabled or disabled.