Reloading factory default settings, 5 reloading factory default settings – GeoDesy GD-P1000E1000 User Manual
Page 34

34
GeoDesy Kft.
Telefon: 06-1-481-2050
H-1116 Budapest, Kondorfa str. 6-8.
Fax.: 06-1-481-2049
E-mail: [email protected]
http://www.geodesy.hu
Log off the FTP server
Now the Update button will be active
Click on update and the update process will start it takes upto 60 seconds. The LEDs
on the back of the device will go off than lit one after the other.
Make sure that the system power is fixed and the power will not go off during the
update process. If the LEDs froze, wait 2-3 minutes before unplugging the power
cable, and repluging again.
10.5 Reloading factory default settings
Should you need to reload the original factory settings follow the steps below.
1. turn ON the switch of Power Adapter
2. wait 3 seconds
3. then turn OFF the switch of the Power Adapter
4. above procedure 3 times.
5. plug turn ON the Power Adapter an leave it turned ON
After this the system resets the following information to the factory default.
- IP address
- Username
- Password
- Device name
- SNMP settings
- Alerts
- Auto MDI/MDIX
-
NPASD (if avialable):
if the reciver does not detect sufficient light power, then
in the head would switch off the network connection signal. Note: During this
perid the 100MB/s laser heads MGM will not be available.