beautypg.com

Alignment of the px1000e1000, Lcd screens, 2 lcd screens – GeoDesy GD-P1000E1000 User Manual

Page 17

background image

17

GeoDesy Kft.

Telefon: 06-1-481-2050

H-1116 Budapest, Kondorfa str. 6-8.

Fax.: 06-1-481-2049

E-mail: [email protected]

http://www.geodesy.hu

7.1.1 Alignment of the PX1000E1000


The first step after the unit was placed to

the bracket, and the units facing each other.

On the back of the receiver you can find the
LEDs and LCD screen for the local received
level and the remote received level.

This help will be very useful because as soon as you have received

– which is very

easy to achieve

– you can see the effect of your local sides movement to the other

side. For further information please check the Meanings of the LCDs chapter.

7.2 LCD screens

Power: The head is powered up.
RX-OK:

Received

beam

is

good

for

communication.
TP Lk: Copper link between the head and the
Network equipment.
R-LS: The recived signal form the remote end
is modulated and .
RV/T-LS:
Remote end is visible for the management system and there is TP
connected to remote end

– same as TP-Lk but displays it on the remote end.

Please press the button on the backside of the unit to scroll between the screens!

1.screen
Loc (local level): Light received from the remote end.

Rem (remote level):

Remote Sites Received level.

Op: optimal
Ov: overload

2.screen
HeadSN: The laser head serial number
0000001

3.screen
Temperature: Temperature inside the laser head.
TT°C

4.screen
ACM position
auto/manual ./000 step

5.screen

[email protected]