Automatic water filters, Remier, D. pressure test the installation – Flint & Walling CCF Series Air Induction Water Treatment Systems User Manual
Page 8: Backwash mode, Manual backwash

8
remier
remier
roducts
roducts
P
P
P
P
WATER TREATMENT
®
Automatic Water Filters
D. PRESSURE TEST THE INSTALLATION
The plumbing system can now be checked for any
possible leaks
1. Open the water supply inlet valve very slowly. Once
the mineral tank is full of water, slowly open the
outlet on the bypass. Open a faucet down stream
from the filter & allow the air to escape. DO NOT
INITIATE A BACKWASH UNTIL MEDIA IS SATURATED.
2. Allow water to run until clear. CHECK FOR LEAKS!
3. Plug the unit in.
4. Make sure the power cord is plugged into a properly
grounded wall receptacle.
E. PROgRAMMINg THE CONTROL VALVE
How To Set Time Of Day
The user can set the time of day. Time of day should only
need to be set initially, and after extended power outages
or when daylight saving time begins or ends and at the
time of start-up. If an extended power outage occurs, the
time of day will flash on and off which indicates the time
of day should be reset.
STEP 1U - press
SET
HOUR
.
STEP 2U - Current Time (hour):
Set the hour of the day using
or
buttons. AM/PM toggles
after 12.
STEP 3U - press
SET
HOUR
button to
complete and return to display
mode.
How To Change Time of Backwash and Days
Between Backwashes
STEP 1 - From normal mode,
press
SET
HOUR
&
buttons
simultaneously for 3 seconds and
release.
STEP 1A - Backwash Time:
Set the clock to the hour the
backwash should occur by using the
and
buttons. An arrow will point to p.m. after 12 (factory
default is 1 a.m.). Press
SET
HOUR
to go to step 1B.
STEP 1B - Setting Days Between Backwash:
Use the
and
buttons to set the days between
backwashes (factory default is 3 days).
Press
SET
HOUR
to return to Normal mode.
Backwash Mode
Typically a system is set to backwash at a time of low
water usage. An example of a time with low water usage
is when a household is asleep. If there is a demand for
water when the system is backwashing, untreated water
will be used.
When the system begins to backwash, the display will
change to include information about the step of the
backwash process. The system runs through the steps
automatically and will reset itself to provide treated
water when the backwash has been completed.
Manual Backwash
Sometimes there is a need to
backwash the system, sooner than
when the system calls for it, usually
referred to as manual backwash.
To initiate a manual backwash at
the preset delayed backwash time,
press and release
and
simultaneously. An arrow point on
the display indicates that the system
will backwash at the preset delayed backwash time. If you
pressed the
and
buttons in error, pressing the
buttons again will cancel the request.
To initiate a manual backwash immediately, press and
hold the
and
buttons simultaneously for four
seconds. The system will begin to backwash immediately.
The request cannot be cancelled. You can manually step
through individual cycles by pressing the
button until
display reaches normal mode.
Power Loss
If the power goes out for less than two hours, the system
will automatically reset itself. If an extended power
outage occurs, the time of day will flash on and off which
indicates the time of day should be reset. The system will
retain the other information entered by your plumbing
professional.
SET
HOUR
REGEN
MIN. FILL
REGEN
HOUR
TIME-HOUR
PM
DAYS TO
REGEN
3
OR
SET
HOUR
REGEN
MIN. FILL
REGEN
HOUR
TIME-HOUR
PM
DAYS TO
REGEN
1
IL1042
SET
HOUR
REGEN
MIN. FILL
REGEN
HOUR
TIME-HOUR
PM
DAYS TO
REGEN
3
IL1075
SET
HOUR
REGEN
MIN. FILL
REGEN
HOUR
TIME-HOUR
PM
DAYS TO
REGEN
3
OR
IL1074
SET
HOUR
REGEN
MIN. FILL
REGEN
HOUR
TIME-HOUR
PM
DAYS TO
REGEN
3
IL1075