Automatic water filters, Remier, Typical w ater cbw installation – Flint & Walling CCF Series Air Induction Water Treatment Systems User Manual
Page 2

2
remier
remier
roducts
roducts
P
P
P
P
WATER TREATMENT
®
Automatic Water Filters
Filter T
ank
Assembly
Sanitary Drain, Floor Drain or Laundry
Tubs are acceptable.
Do not make a direct connection to the drain.
An air gap must
be present.
Cold filtered water inlet 30 p.s.i. minimum pressure 1” minimum pipe size
Maximum drain pipe elevation above drain port is 5 ft.
High Pressure W
arning:
If feedwater pressure is known to be above 125 psi, it is strongly recommended that a pressure reducing valve be installed at this point.
Unfiltered water to Sprinklers and any dersired unfiltered fixtures
Ground Strap
Filter W
ater Outlet
Manual Outlet V
alve
(optional)
110-125 V
olt
Continuous Power Supply
Transformer
Manual Bypass V
alve
(Normally Closed) (optional)
Manual Inlet V
alve
(optional)
Drain Port
Drain line 1/2” ID diameter minimum size
Connection to sanitary sewer line (optional)
Air gap device
Sanitary sewer line
Drain T
rap
Drain
IL1037
Typical W
ater CBW Installation