Installation (Continued)

Proper rotation of
pump impeller is
critical on three

phase motors. See Motor Rotation
under Operation section and Figure 12.

WIRING
1. Install, ground, wire and maintain

this pump in accordance with
your local electrical code and
all other codes and ordinances
that apply. Consult your local
building inspector for local code
information.

2. Ground the pump permanently

using a wire of size and type
specified by local or United States
National Electrical Code. Do not
ground to a gas supply line.

3. Connect ground wire first.

Connect to ground first, then to
green grounding terminal provided
on the motor frame, identified as
GRD. Ground connection MUST
be made to this terminal. Do not
connect motor to electrical power
supply until unit is permanently
grounded; otherwise serious or
fatal electrical shock hazard may
be caused.

4. Connect the other end of the

ground wire to a properly
grounded service panel or to a
control panel ground bar if it is
connected to the power supply
ground.

IMPORTANT: Check local and/or
United States National Electric Codes
for proper grounding information.

Make certain that
the power supply
conforms to the

electrical specifications of the motor
supplied. See Motor Data Charts.

Ground motor

before connecting
to electrical power
supply.

Failure to

ground motor can
cause severe or
fatal electrical shock
hazard.

Do not ground

to a gas supply line.

Pump used to boost incoming pressure from a wall hydrant (manual operation).

Figure 8

IL0424

Wall Hydrant

Hose Adapter

Pressure Gauge

Pressure
Relief Valve

Hose Adapter

High Pressure Reinforced Hose

Spray
Nozzle

Service Tee

Outlet

Inlet

High Pressure Reinforced Hose

Hazardous
voltage. Can
shock, burn or
cause death.
Ground pump
before connecting
to power supply.

!

NOTE: Single voltage (230V) motor, and can not
be connected to 115V.
Figure 10 - Wiring Diagram for Single Phase
3 HP Motors

L1

L2

A

B

IL0181

230 Volts

Single Phase

YELLOW

GRAY

LINE

L1

L2

A

B

L1

L2

A

B

IL0180

YELLOW

115 VOLT

SINGLE PHASE

LINE

230 VOLT

SINGLE PHASE

LINE

WHITE

GRAY

RED

TAN

YELLOW

WHITE

GRAY

RED

TAN

NOTE: Dual voltage motors, change the red and
gray wire to the voltage required.

Figure 9 - Wiring Diagram for Single Phase 1/3 - 2 HP